Summary for Test 2025-12-05-63-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000762 DEA: 11430364 EFIS: 1118000109 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-79-20.2/53.0 |
| Award Date | 03/19/2025 |
| Closeout Date | Not set |
| Work Description | CULVERT REPAIR, GUARDRAIL, FLASHING BEACON AND SIGN REPLACEMENTS. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM WEST JUNCTION ROUTE 78 TO RIVERSIDE COUNTY LINE |
| QA Service Level | 1 (Verified on 05/02/2025) |
Sample Information
| Sample Taken Date | 12/05/2025 | Sample Unique Key | 63 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Plant Sample |
| The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mohammed | Last name of sampler or witnessed by | Masud |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 23417105 | |
| Binder content (%) | 0.0 | Virgin binder PG | PG58-16 |
| Design binder PG | PG58-16 | Binder Supplier | Valero |
| RAP content (%) | Not set | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2025-12-05-63
DIME Test ID: 2025-12-05-63-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-02-23
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 02/10/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4035.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6140.1 g
Mass of HMA Sample prior to ignition: 2104.2 g
Mass Loss: 106.3 g
Mass of aggregate remaining after ignition: 1997.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.17 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.88 %
General comments (publicly viewable) (Max 1000 characters): 4.88 is close to 4.45%
Complies
Test was verified on 2/23/2026 ✔