Summary for Test 2026-02-10-3-1
Test performed: ASTM C1064-17Project Information
| Project Identifiers | Project ID: 1001329 DEA: 100X7404 EFIS: 1013000008 |
|---|---|
| DIST-CO-RTE-PM | 10-CAL-12-17.1/17.5 |
| Award Date | 09/03/2025 |
| Closeout Date | Not set |
| Work Description | BRIDGE REPLACEMENT. |
| Location Description | CALAVERAS COUNTY NEAR SAN ANDREAS FROM 0.2 MILE WEST OF NORTH FORK CALAVERAS RIVER BRIDGE TO 0.2 MILE EAST OF NORTH CALAVERAS RIVER BRIDGE |
| QA Service Level | 1 (Verified on 06/16/2025) |
Sample Information
| Sample Taken Date | 02/10/2026 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/10/2026 | Sample type | Quality Control |
| A brief description of the sample | 1 cubic foot | The quantity of what the sample constitutes | 1 cubic foot |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Patrick |
| Last name of sampler or witnessed by | Baddu | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | ConFab Lathrop | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | K98CP1L |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 3395 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Bed 5, 3rd Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-02-10-3
DIME Test ID: 2026-02-10-3-1
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2026-02-10
Test Results
Input Type: Calculated
Tester's full name: Patrick Wright
Date of test: 02/10/2026
Temperature: 65 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/10/2026 ✔