Summary for Test 2026-01-23-16-2
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 1000785 DEA: 081J3204 EFIS: 0818000017 COOP: NONE |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-74-17.8 |
| Award Date | 05/29/2025 |
| Closeout Date | Not set |
| Work Description | BUILDING WORK, WROUGHT IRON FENCE, HOT MIX ASPHALT, & AGGREGATE BASE. |
| Location Description | RIVERSIDE COUNTY NEAR LAKE ELSINORE AT LAKE ELSINORE MAINTENANCE STATION AT 18745 CONARD AVENUE |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 01/23/2026 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/26/2026 |
| Sample type | Quality Assurance | A brief description of the sample | CONCRETE CYLINDERS |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | DENNIS | Last name of sampler or witnessed by | PARKER |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 1087-12 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | NATIONWIDE | Transportation Laboratory (TL) Number | 1087-12 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SC59033 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | NA | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | CT MAINT FACILITY | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-01-23-16
DIME Test ID: 2026-01-23-16-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-02-06
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Mendez
Date of test: 02/06/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Maximum load on cylinder 1: 46870 lb
Maximum load on cylinder 2: 74780 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 14 days
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Compressive strength of cylinder 1: 3728.7 psi
Compressive strength of cylinder 2: 5949.1 psi
Compressive strength (to nearest 10 psi): 4840 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2026 ✔