Summary for Test 2025-12-14-5-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date12/14/2025 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing12/15/2025 Sample typeQuality Control
A brief description of the samplestructural concrete The quantity of what the sample constitutes1 per batch
From where was the sample collectedJob Site First name of sampler or witnessed byholland
Last name of sampler or witnessed bycantu Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namecemex escondido
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1634525
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected41506539
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedMar Vista Bridge Overhang EB Side Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-12-14-5
DIME Test ID: 2025-12-14-5-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-02-04

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Manuel Mora
Date of test: 01/11/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 168200 lb
Maximum load on cylinder 2: 175410 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6080 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/4/2026 ✔