Summary for Test 2018-01-18-2-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212706 DEA: 051J4004 EFIS: 0517000095 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR,SCR-9-11.0, 11.00 |
| Award Date | 09/06/2017 |
| Closeout Date | 09/20/2022 |
| Work Description | Repair Slipout damage by constructing sidehill viaduct |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/18/2017) |
Sample Information
| Sample Taken Date | 01/18/2018 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/18/2018 | Sample type | Quality Assurance |
| A brief description of the sample | Resistance Butt Welded Hoops | The quantity of what the sample constitutes | 300 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Ed |
| Last name of sampler or witnessed by | Fleming | Title of sampler | TET |
| Telephone number of sampler | 707-310-2029 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Harris Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-103-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 591865 |
| Hoop Manufacturer Lot Number(s) | H01 H02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 6 |
| Diameter of Hoop | 1'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Evraz |
| Welding Company | Harris Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-01-18-2
DIME Test ID: 2018-01-18-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-01-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/18/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | H01 | #6/19mm | 0.44 | 42180 | 95860 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/19/2018 ✔