Summary for Test 2026-01-16-27-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 1000786
DEA: 081J4504
EFIS: 0818000043
DIST-CO-RTE-PM08-RIV-243-0.0/29.7
Award Date03/07/2025
Closeout DateNot set
Work DescriptionHMA, THERMOPLASTIC TRAFFIC STRIPE, AND COLD PLANE AC PAVEMENT.
Location DescriptionRIVERSIDE COUNTY FROM ROUTE 74 AT MOUNTAIN CENTER TO ROUTE 10 IN BANNING
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date01/16/2026 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/21/2026
Sample typeVerification A brief description of the sampleJMF 3/4" WMA A R15 0.40% EVO
The quantity of what the sample constitutes4 bags coldfeed aggs, 2 bags RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byMaryanna Last name of sampler or witnessed by Landaverde
Title of sampler Telephone number of sampler
Laboratory sample identification0105A-26 Linked DIME Sample ID
The fabricator/manufacturer/facility nameIngevity, SJR, Corona Quarry Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at AAA Perris
Where the material sample would have been placed if not sampledAsphalt paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number103819 PERRIS Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-01-16-27
DIME Test ID: 2026-01-16-27-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2026-04-03

Test Results


Input Type: Measured
Tester's full name: Julius Esonwune
Date of test: 01/23/2026
Mass of saturated surface dry sample (before pycnometer) (S): 500.0 grams
Mass of the pycnometer with water and aggregate (C): 959.4 grams
Mass of the pycnometer with water (B): 647.5 grams
Mass of the oven dried sample (before pycnometer) (A): 487.8 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.0 grams
Mass of the oven dry aggregate (for absorption) (A): 487.8 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.593
Bulk specific gravity (SSD Basis): 2.658
Apparent specific gravity: 2.773
Absorption: 2.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/3/2026