Summary for Test 2026-01-16-5-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
| Sample Taken Date | 01/16/2026 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/22/2026 | Sample type | Quality Assurance |
| A brief description of the sample | #9 HRC 150 T-HEADS | The quantity of what the sample constitutes | 828 T-HEADS |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Johnathan |
| Last name of sampler or witnessed by | Shoulders | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Headed Reinforcement Corporation (HRC) | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 323925 | Head Manufacturer Lot Number(s) | 400000945421 |
| Rebar Size | #9 | Headed Bar Model Name | HRC 150 T Heads |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | Cascade Steel |
| Head Manufacturer | Nucor | Head Fabricator | HRC Fountain Valley |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Test Details
DIME Sample ID: 2026-01-16-5
DIME Test ID: 2026-01-16-5-1
Testing Lab: Kleinfelder - Rancho Cordova
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-02-02
Test Results
Number of Headed Bar Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 01/30/2026
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 6 | 1 | 93500 | 93500 | Ok Necking | Kleinfelder |
| 2 | 6 | 1 | 93550 | 93500 | Ok Necking | Kleinfelder |
| 3 | 6 | 1 | 95590 | 95500 | Ok Necking | Kleinfelder |
| 4 | 6 | 1 | 95970 | 96000 | Ok Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/2/2026 ✔