Summary for Test 2026-01-22-10-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000403 DEA: 120K91U4 EFIS: 1222000031 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-91-R9.2/R11.4 |
| Award Date | 01/03/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 08/19/2024) |
Sample Information
| Sample Taken Date | 01/22/2026 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/26/2026 |
| Sample type | Quality Assurance | A brief description of the sample | HRC 500/510 Couplers |
| The quantity of what the sample constitutes | 280 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA Inspector | Telephone number of sampler | 7606866753 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Headed Reinforcement Corporation (HRC) | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-017-26 | Structure unique identifier | |
| Structure name | Bid Item | 3903421 |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Nucor |
| Coupler Manufacturer | Headed Reinforcement Corporation | Intermediate Assembler or Fabricator | |
| Rebar Size | #6 | Coupler Model | HRC 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 100022786140 | Rebar Heat Number(s) | 4154542 |
| Rebar Size 2 | Coupler Unique ID | TP-17-03 |
Test Details
DIME Sample ID: 2026-01-22-10
DIME Test ID: 2026-01-22-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2026-01-28
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 01/28/2026
UTM: NA
Halo ID: NA
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 0.004 | 40140 | 91000 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 0 | 40950 | 93000 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 0 | 41050 | 93500 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 0 | 41970 | 95500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/28/2026 ✔