Summary for Test 2026-01-21-12-11
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-5.1/8.3 |
| Award Date | 01/29/2024 |
| Closeout Date | Not set |
| Work Description | SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/21/2024) |
Sample Information
| Sample Taken Date | 01/21/2026 | Sample Unique Key | 12 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/22/2026 |
| Sample type | Quality Assurance | A brief description of the sample | Reduced PSU |
| The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mohammed | Last name of sampler or witnessed by | Masud |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | see mix design |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | source | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | 220200 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-01-21-12
DIME Test ID: 2026-01-21-12-11
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2026-02-05
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 01/26/2026
Mass of measure: 189.6 grams
Bulk dry specific gravity: 2.609
Mass of sample and measure #1: 331.1 grams
Mass of sample and measure #2: 330.1 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 141.5 grams
Mass of sample #2: 140.5 grams
Uncompacted voids #1: 45.8 %
Uncompacted voids #2: 46.1 %
Average uncompacted voids: 46.0 %
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 2/5/2026 ✔