Summary for Test 2026-01-21-14-4

Test performed: AASHTO T275-07r12

Project Information

Project IdentifiersProject ID: 994901
DEA: 112T3434
EFIS: 1120000081
DIST-CO-RTE-PM11-SD-805-5.1/8.3
Award Date01/29/2024
Closeout DateNot set
Work DescriptionSOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
QA Service Level1 (Verified on 03/21/2024)

Sample Information

Sample Taken Date01/21/2026 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/22/2026
Sample typeQuality Assurance A brief description of the samplePSU
The quantity of what the sample constitutes16 Boxes From where was the sample collectedSource
First name of sampler or witnessed byMohammed Last name of sampler or witnessed byMasud
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220200 Otay Val
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-01-21-14
DIME Test ID: 2026-01-21-14-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2026-01-27

Test Results


Number of tests: 3
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 01/27/2026
Mass of the dry specimen in air: 4848.4 g
Mass of the dry specimen plus paraffin coating in air: 4888.0 g
Mass of the dry specimen plus paraffin coating in water: 2828.5 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 2 of the dry specimen in air: 4845.2 g
Mass 2 of the dry specimen plus paraffin coating in air: 4881.6 g
Mass 2 of the dry specimen plus paraffin coating in water: 2832.0 g
Specific gravity 2 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 3 of the dry specimen in air: 4847.0 g
Mass 3 of the dry specimen plus paraffin coating in air: 4886.4 g
Mass 3 of the dry specimen plus paraffin coating in water: 2832.5 g
Specific gravity 3 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.406
Bulk Specific Gravity 2: 2.412
Bulk Specific Gravity 3: 2.411
Average Bulk Specific Gravity: 2.410
General comments (publicly viewable) (Max 1000 characters): Complies Target within .91 Tested Low 2.406 and High 2.412

Test was verified on 1/27/2026