Summary for Test 2026-01-15-46-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1000199 DEA: 050N7054 EFIS: 0518000111 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-10.4/11.1 |
| Award Date | 07/23/2024 |
| Closeout Date | Not set |
| Work Description | South Coast 101 HOV Lanes Project 4E South- Santa Barbara |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/14/2024) |
Sample Information
| Sample Taken Date | 01/15/2026 | Sample Unique Key | 46 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/20/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA SP R25 | The quantity of what the sample constitutes | 0-750 Tons |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Jesse |
| Last name of sampler or witnessed by | Gomez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Santa Paula | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 17 | HMA Mix Number | 14342 |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | 25 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-01-15-46
DIME Test ID: 2026-01-15-46-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-02-20
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Cotton Tichy
Date of test: 01/22/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2030.3 g
Mass Loss: 117.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.70 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 482 F
Corrected Asphalt Binder Content: 5.06 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2026 ✔