Summary for Test 2026-01-09-2-19
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 215365 DEA: 120Q9704 EFIS: 1218000010 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-0/11.4 |
| Award Date | 07/27/2023 |
| Closeout Date | Not set |
| Work Description | I-405 improvement project from I-5 to Harbor Boulevard including extend pavement life, improve safety, enhance traffic operation, and incorporate Intelligent Transportation Systems (ITS). |
| Location Description | Orange County I-405 PM 0 - 11.4 |
| QA Service Level | 1 (Verified on 07/01/2021) |
Sample Information
| Sample Taken Date | 01/09/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/20/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2(13)X 1-3/4 A325-1 BOLT HDG |
| The quantity of what the sample constitutes | 410 pcs | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joaquin | Last name of sampler or witnessed by | Moreno |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9095268064 |
| Laboratory sample identification | Linked DIME Sample ID | 2026-01-09-2 | |
| The fabricator/manufacturer/facility name | St.Louis Screw and Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L161-001-26 | Structure unique identifier | |
| Structure name | Bid Item | 3900818 |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0196996 |
|---|---|---|---|
| Heat Number(s) | Bolt-1000231773, Nut-10893760, Wash-141949 | Nut Mfg. Lot Number(s) | Nut-24-23-009 |
| Washer Mfg. Lot Number(s) | Wash-46534-141949 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 1-3/4" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436-1 | Finish | ASTM A153, ASTM F2329 |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | Bolt-W000299970 |
| Rocap Test Requirement(s) | Max. Torque | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2026-01-09-2
DIME Test ID: 2026-01-09-2-19
Testing Lab: Kleinfelder - Rancho Cordova
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-01-26
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 01/26/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | W000299970 | 0.5 | 19890 | 0 | 0 | NA | Kleinfelder |
| 2 | 1B | W000299970 | 0.5 | 19930 | 0 | 0 | NA | Kleinfelder |
| 3 | 1C | W000299970 | 0.5 | 20420 | 0 | 0 | NA | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/26/2026 ✔