Summary for Test 2018-01-08-1-2
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 213020 DEA: 07343301 EFIS: 0718000009 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-60-VAR |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 01/05/2018) |
Sample Information
| Sample Taken Date | 01/08/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/10/2018 |
| Sample type | Per Request | A brief description of the sample | CONCRETE |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | JEFF | Last name of sampler or witnessed by | SULKA |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
| Structure name | Unknown | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 0000000000000000 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 123456 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | 00000000000000000 |
| A detailed description of where the material sample was collected | Jobsite | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-01-08-1
DIME Test ID: 2018-01-08-1-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-01-13
Test Results
Unit system used?: US Units
Number of specimens: 4
Test performed: With no density determined
Input Type: Measured
Tester's full name: LMC
Date of test: 01/13/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 3.30 in
Average diameter of cylinder 2: 3.30 in
Average diameter of cylinder 3: 3.30 in
Average diameter of cylinder 4: 3.30 in
Maximum load on cylinder 1: 29201 lb
Maximum load on cylinder 2: 31998 lb
Maximum load on cylinder 3: 31385 lb
Maximum load on cylinder 4: 31394 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Type of fracture pattern of cylinder 4: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 0.98
Correction factor for cylinder 2: 0.97
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 0.97
Age of specimen: 5 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 8.55 in^2
Cross sectional area of cylinder 2: 8.55 in^2
Cross sectional area of cylinder 3: 8.55 in^2
Cross sectional area of cylinder 4: 8.55 in^2
Compressive strength of cylinder 1: 3347.0 psi
Compressive strength of cylinder 2: 3630.2 psi
Compressive strength of cylinder 3: 3670.8 psi
Compressive strength of cylinder 4: 3561.7 psi
Compressive strength (to nearest 10 psi): 3550 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 4
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 4
Source: Partner Data Point File
Test graph for Cylinder Code 3 of 4
Source: Partner Data Point File
Test graph for Cylinder Code 4 of 4
Test was verified on 1/13/2018 ✔