Summary for Test 2018-01-12-3-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date01/12/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/12/2018 Sample typeVerification
A brief description of the sample3/8-inch RAP The quantity of what the sample constitutesJMF
From where was the sample collectedManufacturer First name of sampler or witnessed bya
Last name of sampler or witnessed bya Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameSNC - Mustang Asphalt Plant
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceMustang Asphalt Plant
Aggregate Size3/8 Aggregate SourceUnknown
RAP StockpileStatic Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2018-01-12-3
DIME Test ID: 2018-01-12-3-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2018-01-19

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Ward Jenkins
Date of test: 01/12/2018
Method Performed: no data
Mass of container filled with water: 7376 grams
Mass of oven-dry sample in air for Sample 1: 1695 grams
Mass of container filled with the sample and water for Sample 1: 8386 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.471
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/12/2018 ✔