Summary for Test 2026-01-16-9-5

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 1000762
DEA: 11430364
EFIS: 1118000109
DIST-CO-RTE-PM11-SD-79-20.2/53.0
Award Date03/19/2025
Closeout DateNot set
Work DescriptionCULVERT REPAIR, GUARDRAIL, FLASHING BEACON AND SIGN REPLACEMENTS.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM WEST JUNCTION ROUTE 78 TO RIVERSIDE COUNTY LINE
QA Service Level1 (Verified on 05/02/2025)

Sample Information

Sample Taken Date01/16/2026 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/16/2026
Sample typeQuality Assurance A brief description of the samplePSU
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byMohammed Last name of sampler or witnessed byMasud
Title of sampler Telephone number of sampler
Laboratory sample identification26-01-16-9 Linked DIME Sample ID2026-01-16-10
The fabricator/manufacturer/facility nameMartin Marietta Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)see mix design
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedsource
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number53417105 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-01-16-9
DIME Test ID: 2026-01-16-9-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2026-01-27

Test Results


Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 01/23/2026
Mass of saturated surface dry sample (before pycnometer) (S): 506.6 grams
Mass of the pycnometer with water and aggregate (C): 990.6 grams
Mass of the pycnometer with water (B): 680.3 grams
Mass of the oven dried sample (before pycnometer) (A): 495.9 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 506.6 grams
Mass of the oven dry aggregate (for absorption) (A): 495.9 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.526
Bulk specific gravity (SSD Basis): 2.581
Apparent specific gravity: 2.672
Absorption: 2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/27/2026