Summary for Test 2026-01-15-5-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000402
DEA: 11430384
EFIS: 1118000114
DIST-CO-RTE-PM11-SD-805-23.7/28.5
Award Date10/09/2024
Closeout DateNot set
Work DescriptionREPLACE DRAINAGE, CONCRETE PAVEMENT, AND MODIFY ELECTRICAL SYSTEMS.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION TO ROUTE 5/805 SEPARATION
QA Service Level1 (Verified on 11/18/2024)

Sample Information

Sample Taken Date01/15/2026 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing01/15/2026 Sample typeQuality Assurance
A brief description of the sampleNormal Production The quantity of what the sample constitutes2 boxes
From where was the sample collectedSource First name of sampler or witnessed byMohammed
Last name of sampler or witnessed byMasud Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Otay
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number320200 Otay Val
Binder content (%)4.9 Virgin binder PG PG58-16
Design binder PG PG 64-16 Binder SupplierValero
RAP content (%)22 WMA AdditivesNo
Antistrip typeNone

Test Details

DIME Sample ID: 2026-01-15-5
DIME Test ID: 2026-01-15-5-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-01-27

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 01/22/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4035.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 5596.2 g
Mass of HMA Sample prior to ignition: 1561.1 g
Mass Loss: 93.4 g
Mass of aggregate remaining after ignition: 1467.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.48 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.50 %
General comments (publicly viewable) (Max 1000 characters): 5.50%>4.9+-0.5 does not comply.

Test was verified on 1/27/2026 ✔