Summary for Test 2026-01-09-40-1
Test performed: CTM 524-March 2013Project Information
| Project Identifiers | Project ID: 1001464 DEA: 072XU404 EFIS: 0725000290 |
|---|---|
| DIST-CO-RTE-PM | 07--101-36.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Replace damaged slabs with ISR-RSC |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/19/2025) |
Sample Information
| Sample Taken Date | 01/09/2026 | Sample Unique Key | 40 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/09/2026 | Sample type | Acceptance |
| A brief description of the sample | 6x6x18 Beams | The quantity of what the sample constitutes | 130 CY |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Kristian |
| Last name of sampler or witnessed by | Lopez | Title of sampler | RMA QC |
| Telephone number of sampler | Laboratory sample identification | 26-0076 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Troop | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | NA |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | NA | |
| Concrete batch plant | TROOP | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-01-09-40
DIME Test ID: 2026-01-09-40-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2026-01-20
Test Results
Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 01/12/2026
Identification number: 1
Width of specimen: 6.125 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9268 lb
Maximum load applied 2: 10742 lb
Maximum load applied 3: 9625 lb
Curing history and apparent moisture condition of the specimen: damp
If specimen was capped, ground or if leather shims were used: NO
Defects in specimen, including numbers of beams discarded during test: NONE
Age of specimen: 3 days
Age of specimen in hours: 0 hours
Modulus of rupture: 780 psi
Modulus of rupture 2: 890 psi
Modulus of rupture 3: 820 psi
Modulus of rupture average: 830 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/20/2026 ✔