Summary for Test 2026-01-08-3-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-5.1/8.3 |
| Award Date | 01/29/2024 |
| Closeout Date | Not set |
| Work Description | SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/21/2024) |
Sample Information
| Sample Taken Date | 01/08/2026 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/13/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #8 3'-6"dia. welded hoop |
| The quantity of what the sample constitutes | 52 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Jayce | Last name of sampler or witnessed by | Groves |
| Title of sampler | QA Inspector | Telephone number of sampler | 7606866753 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L196-005-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 313024 |
| Hoop Manufacturer Lot Number(s) | Lot 02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #8 |
| Diameter of Hoop | 3'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade Steel |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-01-08-3
DIME Test ID: 2026-01-08-3-1
Testing Lab: Kleinfelder - Rancho Cordova
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-01-20
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 01/16/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 313024 | 8 | 0.79 | 75680 | 96000 | Okay Necking | Kleinfelder |
| 2 | 2 | 313024 | 8 | 0.79 | 74840 | 94500 | Okay Necking | Kleinfelder |
| 3 | 3 | 313024 | 8 | 0.79 | 74580 | 94500 | Okay Necking | Kleinfelder |
| 4 | 4 | 313024 | 8 | 0.79 | 74150 | 94000 | Okay Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/20/2026 ✔