Summary for Test 2018-01-09-1-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212716 DEA: 101F7904 EFIS: 1016000114 MINOR: 10A1874 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-99-5.8 |
| Award Date | Not set |
| Closeout Date | 12/29/2022 |
| Work Description | Install Bridge Mounted Sign |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 12/20/2018) |
Sample Information
| Sample Taken Date | 01/09/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/11/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Bridge mount sign hardware |
| The quantity of what the sample constitutes | 22 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 562-440-7716 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-004-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 061217A |
|---|---|---|---|
| Heat Number(s) | 100786273 | Nut Mfg. Lot Number(s) | 365483B |
| Washer Mfg. Lot Number(s) | D1287 | Bolt Specification | A325 |
| Bolt Length(s) | 2-1/2" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Mech Galv |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 387302A |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-01-09-1
DIME Test ID: 2018-01-09-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-01-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/11/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | N/A | ?\" | 50475 | 224.52 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 1/11/2018 ✔