Summary for Test 2025-09-05-101-7

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001219
DEA: 021J8904
EFIS: 0221000006
DIST-CO-RTE-PM02-SHA-5-R30.5/R31.0
Award Date07/02/2025
Closeout DateNot set
Work DescriptionREPLACE PAVEMENT AND PLACE POLYESTER CONCRETE OVERLAY.
Location DescriptionSHASTA COUNTY NEAR O\'BRIEN FROM 0.1 MILE SOUTH OF TUNNEL GULCH VIADUCT TO THE O\'BRIEN REST AREA
QA Service Level1 (Verified on 05/05/2025)

Sample Information

Sample Taken Date09/05/2025 Sample Unique Key101
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2025
Sample typeQuality Control A brief description of the sample4 x 8 Concrete Cylinders
The quantity of what the sample constitutes20 From where was the sample collectedJob Site
First name of sampler or witnessed byBrent Last name of sampler or witnessed byVan-Y
Title of sampler Telephone number of sampler
Laboratory sample identification80373-1 TP Set 1 Linked DIME Sample ID
The fabricator/manufacturer/facility namePrecision Concrete Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number80373-1 TP
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedPrecision Concrete Yard Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-09-05-101
DIME Test ID: 2025-09-05-101-7
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-04-09

Test Results


Unit system used?: US Units
Number of specimens: 5
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Travis Van-Y
Date of test: 10/03/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Average diameter of cylinder 4: 4.00 in
Average diameter of cylinder 5: 4.00 in
Maximum load on cylinder 1: 72360 lb
Maximum load on cylinder 2: 76120 lb
Maximum load on cylinder 3: 73580 lb
Maximum load on cylinder 4: 70410 lb
Maximum load on cylinder 5: 73360 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Type of fracture pattern of cylinder 4: 2
Type of fracture pattern of cylinder 5: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Correction factor for cylinder 5: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Cross sectional area of cylinder 4: 12.57 in^2
Cross sectional area of cylinder 5: 12.57 in^2
Compressive strength (to nearest 10 psi): 5820 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/9/2026