Summary for Test 2026-01-15-2-2

Test performed: CTM 518-June 2010

Project Information

Project IdentifiersProject ID: 994901
DEA: 112T3434
EFIS: 1120000081
DIST-CO-RTE-PM11-SD-805-5.1/8.3
Award Date01/29/2024
Closeout DateNot set
Work DescriptionSOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
QA Service Level1 (Verified on 03/21/2024)

Sample Information

Sample Taken Date01/15/2026 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/15/2026
Sample typeQuality Assurance A brief description of the sampleField Sample
The quantity of what the sample constitutesField Sample From where was the sample collectedSource
First name of sampler or witnessed byDaniel Paul Last name of sampler or witnessed bySmith
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAssociated Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number55723740
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedField Sample Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-01-15-2
DIME Test ID: 2026-01-15-2-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Test Release Date: 2026-01-21

Test Results


Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 01/15/2026
Calibration factor: 1
Weight of (Measure + Concrete + Cover Plate): 96.39 lb
Weight of (Measure + Cover Plate): 23.45 lb
Total weight of cement: 4020 lb
Total weight of fine aggregate: 19137 lb
Total weight of coarse aggregate: 14280 lb
Total weight of water added during mixing: 1943 lb
Kelly Ball Penetration of the batch of concrete tested: 3.5 inch
Air content by the pressure method: 1.6 %
Station number or portion of the structure in which the concrete was placed: NB I-805 Abut # 2 Naples St UC
Net weight of concrete: 72.94 lb
Total weight of all material in the mix: 39380 lb
Volume of the concrete: 19.996 yd^3
Unit weight of the concrete: 72.94 lb/ft^3
Cement content: 201.04 lb/yd^3
General comments (publicly viewable) (Max 1000 characters): Not Applicable