Summary for Test 2026-01-06-10-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000612 DEA: 120R57U4 EFIS: 1223000131 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-11.4/24.2 |
| Award Date | 01/14/2025 |
| Closeout Date | Not set |
| Work Description | PLACE JPCP (RSC) AND RHMA, AND MODIFY ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY FROM HARBOR BOULEVARD UNDERCROSSING IN COSTA MESA TO LOS ANGELES COUNTY LINE AT ROSSMOOR |
| QA Service Level | 1 (Verified on 09/30/2024) |
Sample Information
| Sample Taken Date | 01/06/2026 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/13/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #6 Spliced Rebar |
| The quantity of what the sample constitutes | 239 | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Maribel | Last name of sampler or witnessed by | Munoz |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Next Century Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Cascade |
| Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | |
| Rebar Size | #6 | Coupler Model | D340 Taper Lock |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 6940 | Rebar Heat Number(s) | 479425 |
| Rebar Size 2 | Coupler Unique ID | ST-17-13 |
Test Details
DIME Sample ID: 2026-01-06-10
DIME Test ID: 2026-01-06-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2026-01-21
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 01/15/2026
UTM: NA
Halo ID: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 479425 | 6 | 0.44 | 0.003 | 40310 | 91500 | NA | Kleinfelder |
| 2 | 2 | 479425 | 6 | 0.44 | 0 | 40980 | 93000 | NA | Kleinfelder |
| 3 | 3 | 479425 | 6 | 0.44 | 0 | 41450 | 94000 | NA | Kleinfelder |
| 4 | 4 | 479425 | 6 | 0.44 | 0 | 41000 | 93000 | NA | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/21/2026 ✔