Summary for Test 2025-12-11-42-4

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date12/11/2025 Sample Unique Key42
Date that the sample was received by the laboratory/organization performing the testing12/12/2025 Sample typeAcceptance
A brief description of the sample1"xNo.4 & WCS Aggregate PCC The quantity of what the sample constitutes27 CY
From where was the sample collectedManufacturer First name of sampler or witnessed byIdris
Last name of sampler or witnessed byNajjar Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVanguard Mobile Batch Plant at I-215 NB / SR-60 WB
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0027
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpiles at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberHE4X4BM Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-12-11-42
DIME Test ID: 2025-12-11-42-4
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2026-01-14

Test Results


Input Type: Measured
Tester's full name: Robert Jarquin
Date of test: 12/16/2025
Wet weight of the sample: 1680.5000000000 grams
Dry weight of the sample: 1581.7000000000 grams
Weight of water in sample: 98.8000000000 grams
Percent moisture: 6.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/14/2026 ✔