Summary for Test 2025-11-04-99-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000903
DEA: 081M0404
EFIS: 0821000091
DIST-CO-RTE-PM08-SBD-40-R140.0/R142.2
Award Date06/06/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC & RHMA, VEGETATION CONTROL (MINOR CONC), MGS, AND HTCB.
Location DescriptionSAN BERNARDINO COUNTY IN NEEDLES FROM FOX WASH OVERFLOW TO L STREET UNDERCROSSING
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date11/04/2025 Sample Unique Key99
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/04/2025
Sample typeAcceptance A brief description of the sample1 bag of 1" Agg. and 1 bag of Sand
The quantity of what the sample constitutes1 Bag of PCC and 1 Bag of Sand From where was the sample collectedJob Site
First name of sampler or witnessed byFrancisco Last name of sampler or witnessed byRuvalcaba
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameOn Site Volumetric Truck Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Rte. 40 Needles
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedfrom jobsite volumetric truck
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-11-04-99
DIME Test ID: 2025-11-04-99-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-01-12

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Francisco Ruvalcaba
Date of test: 11/07/2025
Sieve SizeCumulative Percent Passing
100 %
100 %
97 %
0 %
40 %
5 %
2 %
General comments (publicly viewable) (Max 1000 characters): # 3/8" sieve is out of Operating range.