Summary for Test 2025-12-18-69-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-5.1/8.3 |
| Award Date | 01/29/2024 |
| Closeout Date | Not set |
| Work Description | SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/21/2024) |
Sample Information
| Sample Taken Date | 12/18/2025 | Sample Unique Key | 69 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/19/2025 | Sample type | Production Start-Up |
| A brief description of the sample | PSU | The quantity of what the sample constitutes | 3 bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Mohammed |
| Last name of sampler or witnessed by | Masud | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Otay | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 220200 Otay Val |
Test Details
DIME Sample ID: 2025-12-18-69
DIME Test ID: 2025-12-18-69-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-01-14
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 01/02/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 2565.4 grams
Mass of container filled with the sample and water for Sample 1: 9022.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.52
Theoretical maximum density at 25°C (77°F): 2512.7 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 1/14/2026 ✔