Summary for Test 2026-01-09-24-8
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-L1.8/L3.2 |
| Award Date | 06/20/2025 |
| Closeout Date | Not set |
| Work Description | Construct I-80 WB Truck Scales |
| Location Description | CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI |
| QA Service Level | 1 (Verified on 07/10/2025) |
Sample Information
| Sample Taken Date | 01/09/2026 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1" x #4 pcc agg |
| The quantity of what the sample constitutes | 270 CY | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Christian | Last name of sampler or witnessed by | Sousa |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Central Lake Herman | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Orca / Vulcan Pleasanton |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-01-09-24
DIME Test ID: 2026-01-09-24-8
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-01-12
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Henry Concepcion
Date of test: 01/09/2026
Clay Level (Test 1): 39
Sand Level (Test 1): 35
Clay Level (Test 2): 40
Sand Level (Test 2): 36
Clay Level (Test 3): 41
Sand Level (Test 3): 35
Sand Equivalent (Test 1): 90
Sand Equivalent (Test 2): 90
Sand Equivalent (Test 3): 86
Sand Equivalent: 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/12/2026 ✔