Summary for Test 2026-01-07-22-2

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000903
DEA: 081M0404
EFIS: 0821000091
DIST-CO-RTE-PM08-SBD-40-R140.0/R142.2
Award Date06/06/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC & RHMA, VEGETATION CONTROL (MINOR CONC), MGS, AND HTCB.
Location DescriptionSAN BERNARDINO COUNTY IN NEEDLES FROM FOX WASH OVERFLOW TO L STREET UNDERCROSSING
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date01/07/2026 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing01/08/2026 Sample typeAcceptance
A brief description of the sample1"x#4, WCS The quantity of what the sample constitutes2 bags
From where was the sample collectedJob Site First name of sampler or witnessed byChijioke
Last name of sampler or witnessed byOkoroanyanwu Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameINTERSTATE CIVIL, Volumetric Truck
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Jobsite
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedField Stockpile.
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberICVT-4000 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-01-07-22
DIME Test ID: 2026-01-07-22-2
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-01-09

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Francisco Ruvalcaba
Date of test: 01/08/2026
Sieve SizeCumulative Percent Passing
100 %
100 %
96 %
0 %
13 %
2 %
1 %
General comments (publicly viewable) (Max 1000 characters): Coarse Aggregates