Summary for Test 2025-07-14-87-5
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1000824 DEA: 021K0204 EFIS: 0224000043 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-53.5/61.0 |
| Award Date | 02/05/2025 |
| Closeout Date | 11/25/2025 |
| Work Description | PLACE AR CHIP SEAL AND REPLACE ASPHALT CONCRETE SURFACING. |
| Location Description | TRINITY COUNTY IN AND NEAR WEAVERVILLE AND AT AND NEAR DOUGLAS CITY FROM 0.1 MILE WEST OF INDUSTRIAL PARKWAY TO STEEL BRIDGE ROAD |
| QA Service Level | 1 (Verified on 12/04/2024) |
Sample Information
| Sample Taken Date | 07/14/2025 | Sample Unique Key | 87 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 16 boxes of Lime Treated 1/2-inch Type A HMA (eq. PG 64-16) |
| The quantity of what the sample constitutes | Production Start Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Sturgis |
| Title of sampler | PEI | Telephone number of sampler | |
| Laboratory sample identification | D79959 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | Transportation Laboratory (TL) Number | 858523 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 5.2 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 64-16 | Binder Supplier | Valero (Benicia, CA) |
| RAP content (%) | 25 | WMA Additives | No |
| Antistrip type | Lime |
Test Details
DIME Sample ID: 2025-07-14-87
DIME Test ID: 2025-07-14-87-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2026-01-06
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 07/25/2025
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: 7.1 %
Air Void Content for specimen A-2: 6.9 %
Air Void Content for specimen B-1: 6.9 %
Air Void Content for specimen B-2: 7.1 %
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 1.13 mm
Maximum impression at 5000 passes (right wheel): 1.09 mm
Average impression at 5000 passes (left/right avg): 1.11 mm
Maximum impression at 10000 passes (left wheel): 1.35 mm
Maximum impression at 10000 passes (right wheel): 1.27 mm
Average impression at 10000 passes (left/right avg): 1.31 mm
Maximum impression at 15000 passes (left wheel): 1.52 mm
Maximum impression at 15000 passes (right wheel): 1.42 mm
Average impression at 15000 passes (left/right avg): 1.47 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): CT 360:
SA=0.5g/cm²,
CT 389:
Rut=0.1in.@N15000,
Nf>15000,
SIP>15000
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| D79959, 858523, 02-1K0203, HWT | 812.00 KB | 01/06/2026 | 2025-07-14-87-5 | Info |
Test was verified on 1/6/2026 ✔