Summary for Test 2017-12-20-2-9
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211784 DEA: 11085784 EFIS: 1100000064 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-163-4.1/4.9 |
| Award Date | 06/16/2017 |
| Closeout Date | 08/10/2021 |
| Work Description | INTERCHANGE MODIFICATION AND OVERCROSSING WIDENING. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 09/05/2017) |
Sample Information
| Sample Taken Date | 12/20/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/04/2018 | Sample type | Recertification |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 1 lot |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | greg |
| Last name of sampler or witnessed by | johnston | Title of sampler | QA |
| Telephone number of sampler | 9165247768 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | CMC Rbar |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L53-220-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4071355 4070468 4067791 4063303 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 4 6 8 9 |
| Diameter of Hoop | 2'0' 5'0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
| Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-12-20-2
DIME Test ID: 2017-12-20-2-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-01-31
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/08/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Cycle-1 | 100 | #8/25mm | 2 | 0.79 | 74208 | 93934 | NECKING OK | Fred |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 1/24/2018 ✔