Summary for Test 2025-12-29-5-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001361
DEA: 120M9704
EFIS: 1213000099
DIST-CO-RTE-PM12-ORA-57-11.5/12.5
Award Date09/25/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 07/28/2025)

Sample Information

Sample Taken Date12/29/2025 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing12/29/2025 Sample typeQuality Assurance
A brief description of the sample3/4 WMA-A The quantity of what the sample constitutes3/4 WMA-A
From where was the sample collectedManufacturer First name of sampler or witnessed byJohnny
Last name of sampler or witnessed byDo Title of sampler
Telephone number of sampler Laboratory sample identification25-1192
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-12-29-5
DIME Test ID: 2025-12-29-5-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-01-26

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 01/06/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3863.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 5872.2 g
Mass of HMA Sample prior to ignition: 2009.0 g
Mass Loss: 93.1 g
Mass of aggregate remaining after ignition: 1915.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.63 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
2026AC-SP-0001pdf105.27 KB01/06/20262025-12-29-5-1   Info

Test was verified on 1/26/2026 ✔