Summary for Test 2025-12-05-24-3
Test performed: AASHTO T315-24Project Information
| Project Identifiers | Project ID: 1000997 DEA: 010J2104 EFIS: 0118000190 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-R2.6/23.9 |
| Award Date | 06/06/2025 |
| Closeout Date | Not set |
| Work Description | RHMA, HMA, AND COLD PLANE ASPHALT CONCRETE PAVEMENT. |
| Location Description | DEL NORTE COUNTY IN AND NEAR KLAMATH FROM 1.2 MILES SOUTH OF KLAMATH RIVER OVERFLOW TO 1.1 MILE NORTH OF HAMILTON ROAD |
| QA Service Level | 1 (Verified on 03/21/2025) |
Sample Information
| Sample Taken Date | 12/05/2025 | Sample Unique Key | 24 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/09/2025 | Sample type | Quality Assurance |
| A brief description of the sample | pg 58-22 | The quantity of what the sample constitutes | 1 can of binder |
| From where was the sample collected | Source | First name of sampler or witnessed by | LEE |
| Last name of sampler or witnessed by | R | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SANDY PRAIRIE | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | 026031 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2025-12-05-24
DIME Test ID: 2025-12-05-24-3
Testing Lab: Atlas - Denver
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-01-06
Test Results
Phase: PAV residue
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 01/06/2026
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.01 %
Stress Amplitude: 38.606 kPa
Phase Angle (δ) (for the 10 cycles): 49.2 degree
Complex Modulus (G*) (for the 10 measurements): 3841.255 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 2908 kPa
General comments (publicly viewable) (Max 1000 characters): PAV
Test was verified on 1/6/2026 ✔