Summary for Test 2025-12-01-19-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075 |
|---|---|
| DIST-CO-RTE-PM | 03-SOL,YOL-50,80,113-Var |
| Award Date | 09/27/2024 |
| Closeout Date | Not set |
| Work Description | HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS. |
| Location Description | SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/17/2024) |
Sample Information
| Sample Taken Date | 12/01/2025 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 12/18/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" WMA-SP w/ RAP |
| The quantity of what the sample constitutes | 10 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Sergio | Last name of sampler or witnessed by | Tostado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 6091 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Teichert Woodland | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 30640432428P |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-12-01-19
DIME Test ID: 2025-12-01-19-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-01-05
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Cody Cordero
Date of test: 12/18/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 2976.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 5086.1 g
Mass of HMA Sample prior to ignition: 2109.4 g
Mass Loss: 127.3 g
Mass of aggregate remaining after ignition: 1982.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.85 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.05 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/5/2026 ✔