Summary for Test 2025-06-26-126-7

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000365
DEA: 033H9014
EFIS: 0323000075
DIST-CO-RTE-PM03-SOL,YOL-50,80,113-Var
Award Date09/27/2024
Closeout DateNot set
Work DescriptionHMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS.
Location DescriptionSOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/17/2024)

Sample Information

Sample Taken Date06/26/2025 Sample Unique Key126
Date that the sample was received by the laboratory/organization performing the testing06/27/2025 Sample typeQuality Control
A brief description of the sample4x8 Cylinders The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byRafael
Last name of sampler or witnessed byDuenas Title of samplerQC Field Technician
Telephone number of sampler Laboratory sample identification1626827 Set 1
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex Fairfield
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameRTE 80, W/B Shoulder, Sign No. A13 STA 443+00
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number16286827
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected0
Concrete batch plantCemex The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedRTE 80, E/B Shoulder, Sign No. A10 STA 401+50 Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2025-06-26-126
DIME Test ID: 2025-06-26-126-7
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-04-09

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Travis Van-Y
Date of test: 07/25/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 100070 lb
Maximum load on cylinder 2: 107540 lb
Maximum load on cylinder 3: 103700 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 8260 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/9/2026 ✔