Summary for Test 2018-01-01-4-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 01/01/2018 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/01/2018 |
| Sample type | Quality Control | A brief description of the sample | Untreated Crushed Fines |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Source |
| First name of sampler or witnessed by | a | Last name of sampler or witnessed by | a |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | 3512 17-02-S1b | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | SNC - Mustang Pit | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | MSHA ID 2602089 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
| The concrete mix design number | Unknown | Lot number | Not set |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2018-01-01-4
DIME Test ID: 2018-01-01-4-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-01-12
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 01/01/2018
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 99.8 % | ||||||
| 99.5 % | ||||||
| 53.1 % | ||||||
| 24.4 % | ||||||
| 14 % | ||||||
| 9.3 % | ||||||
| 7.2 % | ||||||
| 6 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/5/2018 ✔