Summary for Test 2025-12-08-37-6

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1001575
DEA: 061H9604
EFIS: 0625000104
DIST-CO-RTE-PM06-KER-46,119-VAR
Award Date10/22/2025
Closeout Date10/07/2026
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACING RHMA TYPE G.
Location DescriptionKERN COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/15/2025)

Sample Information

Sample Taken Date12/08/2025 Sample Unique Key37
Date that the sample was received by the laboratory/organization performing the testing12/15/2025 Sample typeQuality Assurance
A brief description of the sample70-10 The quantity of what the sample constitutes1 can of binder
From where was the sample collectedSource First name of sampler or witnessed byg
Last name of sampler or witnessed byn/a Title of sampleroperator
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGriffith Edmonston
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form753964
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-12-08-37
DIME Test ID: 2025-12-08-37-6
Testing Lab: WSP USA - Phoenix
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-12-30

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 12/24/2025
Time of test: 00:00 HH:MM
Test Temperature: 135.0 C
Speed: 200 rpm
Spindle size: .463 in
Torque: 32.2 %
Viscosity reading #1 (A) : 402.5 cP
Viscosity reading #2 (B) : 402.5 cP
Viscosity reading #3 (C): 403.75 cP
Average viscosity : 0.403 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOCITY AT 135C

Test was verified on 12/30/2025 ✔