Summary for Test 2025-12-17-27-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 995489
DEA: 07344204
EFIS: 0718000046
DIST-CO-RTE-PM07-LA-5,710-23.2/36.3,21.9
Award Date06/13/2024
Closeout DateNot set
Work DescriptionCONSTRUCT GSRDS, MVPS, AND BIOSWALES.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 01/22/2024)

Sample Information

Sample Taken Date12/17/2025 Sample Unique Key27
Date that the sample was received by the laboratory/organization performing the testing12/19/2025 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byVulcan QC
Last name of sampler or witnessed byVulcan QC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Sun Valley - Blvd.
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-12-17-27
DIME Test ID: 2025-12-17-27-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-12-23

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Hussaya Leelakitrungruang
Date of test: 12/23/2025
Time of test: 8:43 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 55.9 %
Viscosity reading #1 (A) : 0.276 Pa-s
Viscosity reading #2 (B) : 0.279 Pa-s
Viscosity reading #3 (C): 0.285 Pa-s
Average viscosity: 0.28 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/23/2025 ✔