Summary for Test 2017-12-14-8-9
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 209146 DEA: 06471504 EFIS: 0600000464 COOP: 061549 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-39.6/41.3 |
Award Date | 02/24/2017 |
Closeout Date | 03/03/2020 |
Work Description | RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT. |
Location Description | TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD |
QA Service Level | 1 (Verified on 10/08/2013) |
Sample Information
Sample Taken Date | 12/14/2017 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/21/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Gr. 55 Anchor Rod |
The quantity of what the sample constitutes | 25 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Lanz |
Title of sampler | QA | Telephone number of sampler | 707 208-5241 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L-106-023-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
---|---|---|---|
Heat Number(s) | Bolt 3074489, HDG NUT 144210, Plain NUT 3064260, Washer 305358 | Nut Mfg. Lot Number(s) | DYSON HDG, DDBR AmeriBolt Plain, W1380 |
Washer Mfg. Lot Number(s) | Wrought Washer, 305392 | Bolt Specification | F1554-GR 55 |
Bolt Length(s) | 40" | Nut Specification | A563 GR DH |
Washer Specification | F436 | Finish | HDG one end |
Diameter/Size | 2" | Bolt Mfg. Lot Number | MADDEN, NA |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | WAX on Galvanized section |
Test Details
DIME Sample ID: 2017-12-14-8
DIME Test ID: 2017-12-14-8-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-01-12
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 01/04/2018
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 305358
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: WS
Size: 2 in
Bolt Length: no data
Measurement Average: 7.01 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/5/2018 ✔