Summary for Test 2025-11-18-67-1
Test performed: ASTM C39-18Project Information
| Project Identifiers | Project ID: 993678 DEA: 042Q8004 EFIS: 0419000050 COOP: 042836,042944 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101,92-US 101 & SR 92-10.9/12.1 & 11.8/13.4 |
| Award Date | 01/22/2025 |
| Closeout Date | Not set |
| Work Description | US 101/SR 92 INTERCHANGE AREA IMPROVEMENT :PROJECT WILL CONSTRUCT CONGESTION RELIEF IMPROVEMENTS AT THE US 101/SR 92 INTERCHANGE AREA. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/15/2022) |
Sample Information
| Sample Taken Date | 11/18/2025 | Sample Unique Key | 67 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 12/16/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Structural concrete |
| The quantity of what the sample constitutes | 13 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Renata | Last name of sampler or witnessed by | Kovalchuk |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Graniterock | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | WS Ramp (Widen) | Bid Item | 3914832 |
Material Information
| Material Type | Concrete | The concrete mix design number | 57S750 |
|---|---|---|---|
| The truck number from where the sample was collected | 2409 | The batch plant ticket number from where the sample was collected | 147607 |
| Concrete batch plant | Graniterock Redwood City | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | Bent 14 Column |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-11-18-67
DIME Test ID: 2025-11-18-67-1
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-12-16
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Yannick Aranas
Date of test: 12/16/2025
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 83586 lb
Maximum load on cylinder 2: 76527 lb
Maximum load on cylinder 3: 76051 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 6618.1 psi
Compressive strength of cylinder 2: 6088.1 psi
Compressive strength of cylinder 3: 6021.5 psi
Compressive strength (to nearest 10 psi): 6240 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/16/2025 ✔