Summary for Test 2025-09-05-92-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995262
DEA: 041Q4604
EFIS: 0418000279
DIST-CO-RTE-PM04-SCL-280-0/2.7
Award Date05/02/2024
Closeout DateNot set
Work DescriptionRHMA-G SURFACING AND CONSTRUCT BRIDGE APPROACH.
Location DescriptionSANTA CLARA COUNTY IN SAN JOSE FROM ROUTE 280/680/101 SEPARATION TO 0.2 MILE WEST OF BIRD AVENUE OVERCROSSING
QA Service Level1 (Verified on 12/11/2023)

Sample Information

Sample Taken Date09/05/2025 Sample Unique Key92
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/08/2025
Sample typeQuality Assurance A brief description of the sample3/4"RHMA-G
The quantity of what the sample constitutes1500 - 2250 Tons From where was the sample collectedSource
First name of sampler or witnessed byJoe Last name of sampler or witnessed byPuno
Title of samplerQC Tech Telephone number of sampler
Laboratory sample identification SJ-090525-T308-L1SL13 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Sunol Drier Drum Plant Transportation Laboratory (TL) NumberSJ-090525-3
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number13 HMA Mix Number63S4BV 25W1C 8967
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-09-05-92
DIME Test ID: 2025-09-05-92-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-12-27

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Fernando Vega
Date of test: 09/09/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2164.4 g
Mass Loss: 185.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.62 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.76 %
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 13

Test was verified on 12/27/2025