Summary for Test 2025-10-16-80-2
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1001065 DEA: 070Y1304 EFIS: 0724000134 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-25.9/30.6 |
| Award Date | 05/22/2025 |
| Closeout Date | Not set |
| Work Description | MAINLINE INDIVIDUAL SLAB REPLACEMENT. |
| Location Description | VENTURA COUNTY IN VENTURA FROM 0.1 MILE WEST OF TELEPHONE RD UNDERCROSSING TO VENTURA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/01/2025) |
Sample Information
| Sample Taken Date | 10/16/2025 | Sample Unique Key | 80 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2025 |
| Sample type | Acceptance | A brief description of the sample | 3/4 HMA-A |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | MD | Last name of sampler or witnessed by | Shahjahan |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | 25-1148 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Saticoy | Transportation Laboratory (TL) Number | 019027 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220200 SAT LTR | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-10-16-80
DIME Test ID: 2025-10-16-80-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-12-15
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 10/22/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4105.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6143.5 g
Mass of HMA Sample prior to ignition: 2038.5 g
Mass Loss: 98.5 g
Mass of aggregate remaining after ignition: 1940.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.12 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.71 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/15/2025 ✔