Summary for Test 2025-05-29-137-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 1000117
DEA: 020J0104
EFIS: 0219000044
DIST-CO-RTE-PM02-TEH-99-4.2/4.8
Award Date07/11/2024
Closeout DateNot set
Work DescriptionPLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location DescriptionTEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date05/29/2025 Sample Unique Key137
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2025
Sample typeQuality Assurance A brief description of the sample6.3 SK 1" WRA SCM
The quantity of what the sample constitutes6 cylinders-4x8" From where was the sample collectedJob Site
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of sampler TET Telephone number of sampler5306055865
Laboratory sample identification002 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMathews Ready Mix Transportation Laboratory (TL) NumberTL-502-165619
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameBox Culvert Bid Item3907722

Material Information

Material TypeConcrete The concrete mix design number06316P15
The truck number from where the sample was collected0722 The batch plant ticket number from where the sample was collected17034638
Concrete batch plant1619 Chico The fabricator/manufacturer designation for the sampleMathews- order 2015
A detailed description of where the material sample was collectedTruck chute Where the material sample would have been placed if not sampledBox Culvert
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-05-29-137
DIME Test ID: 2025-05-29-137-1
Testing Lab: CT D02 - Red Bluff Field Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-12-15

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Brandon White
Date of test: 06/26/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 59130 lb
Maximum load on cylinder 2: 59300 lb
Maximum load on cylinder 3: 59330 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): Bonded caps
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4700.0 psi
Compressive strength of cylinder 2: 4720.0 psi
Compressive strength of cylinder 3: 4720 psi
Compressive strength (to nearest 10 psi): 4710 psi
Serial number of delivery ticket, if available: 17034638
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/15/2025