Summary for Test 2025-09-14-27-2

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001223
DEA: 070W2104
EFIS: 0721000087
DIST-CO-RTE-PM07-LA-2-R18.7
Award Date06/23/2025
Closeout DateNot set
Work DescriptionPLACE CLASS 3 AGGREGATE BASE AND HOT MIX ASPHALT.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER AT 2901 AT WEST BROADWAY
QA Service Level1 (Verified on 07/02/2025)

Sample Information

Sample Taken Date09/14/2025 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2025
Sample typeAcceptance A brief description of the sample1/2 HMA-A
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byArnold Last name of sampler or witnessed byTruong
Title of samplerMREA Telephone number of sampler
Laboratory sample identification25-1012 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Sun Valley Transportation Laboratory (TL) NumberA915251
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number320200W SVA VLO
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-09-14-27
DIME Test ID: 2025-09-14-27-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-12-12

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 09/19/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3951.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 6010.1 g
Mass of HMA Sample prior to ignition: 2058.4 g
Mass Loss: 119.3 g
Mass of aggregate remaining after ignition: 1939.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.30 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.50 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/12/2025