Summary for Test 2025-12-08-26-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000612 DEA: 120R57U4 EFIS: 1223000131 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-11.4/24.2 |
| Award Date | 01/14/2025 |
| Closeout Date | Not set |
| Work Description | PLACE JPCP (RSC) AND RHMA, AND MODIFY ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY FROM HARBOR BOULEVARD UNDERCROSSING IN COSTA MESA TO LOS ANGELES COUNTY LINE AT ROSSMOOR |
| QA Service Level | 1 (Verified on 09/30/2024) |
Sample Information
| Sample Taken Date | 12/08/2025 | Sample Unique Key | 26 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/08/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 RWMAG | The quantity of what the sample constitutes | 3/4 RWMAG |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Jimmy |
| Last name of sampler or witnessed by | Pham | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 25-1137 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Irwindale | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-12-08-26
DIME Test ID: 2025-12-08-26-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-12-29
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 12/10/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3860.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 5863.1 g
Mass of HMA Sample prior to ignition: 2003.0 g
Mass Loss: 151.4 g
Mass of aggregate remaining after ignition: 1851.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.11 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.45 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 2025AC-SP-0098 | 105.77 KB | 12/11/2025 | 2025-12-08-26-1 | Info |
Test was verified on 12/29/2025 ✔