Summary for Test 2025-12-08-16-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001575
DEA: 061H9604
EFIS: 0625000104
DIST-CO-RTE-PM06-KER-46,119-VAR
Award DateNot set
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACING RHMA TYPE G.
Location DescriptionKERN COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/15/2025)

Sample Information

Sample Taken Date12/08/2025 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/08/2025
Sample typeAcceptance A brief description of the sample3/4" HMA- Type A
The quantity of what the sample constitutesL1SL1- 30 box HMA, 4 bags of cold feed, 4 bags of virgin aggregate and 4 canes of PG70-10 From where was the sample collectedSource
First name of sampler or witnessed byBarrett Last name of sampler or witnessed byFelder
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3933861

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)4.7 Virgin binder PG PG 70-10
Design binder PG PG 64-16 Binder SupplierSan Juaquin Refinery
RAP content (%)15 WMA AdditivesYes
Antistrip typeLIme 0.8%

Test Details

DIME Sample ID: 2025-12-08-16
DIME Test ID: 2025-12-08-16-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-12-09

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Mike Cozad
Date of test: 12/08/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4321.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6459.3 g
Mass of HMA Sample prior to ignition: 2138.1 g
Mass Loss: 135.0 g
Mass of aggregate remaining after ignition: 2003.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.87 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-1H9604_37013_251208_T308_L1SL1pdf167.04 KB12/09/20252025-12-08-16-2   Info

Test was verified on 12/9/2025