Summary for Test 2025-12-02-24-4
Test performed: AASHTO T275-07r12Project Information
| Project Identifiers | Project ID: 994443 DEA: 053307C4 EFIS: 0514000028 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-41,46-44.5/45.3,54.0/57.8 |
| Award Date | 02/27/2023 |
| Closeout Date | Not set |
| Work Description | Wye Segment - Route 41/46 Separation |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 12/16/2022) |
Sample Information
| Sample Taken Date | 12/02/2025 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2025 |
| Sample type | Acceptance | A brief description of the sample | 3 HMA cores |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | SPM QC | Telephone number of sampler | |
| Laboratory sample identification | 251202-L2SL95 ABC | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Papich Construction | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 3857461 |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 95 | HMA Mix Number | L230077A |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-12-02-24
DIME Test ID: 2025-12-02-24-4
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2025-12-05
Test Results
Number of tests: 1
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 12/04/2025
Mass of the dry specimen in air: 921.9 g
Mass of the dry specimen plus paraffin coating in air: 941.1 g
Mass of the dry specimen plus paraffin coating in water: 515.1 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.278
General comments (publicly viewable) (Max 1000 characters): L2 SL95C 93.9%
Test was verified on 12/5/2025 ✔
