Summary for Test 2017-12-20-10-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211616
DEA: 050G0404
EFIS: 0500020020
DIST-CO-RTE-PM05-SLO,MON-101-63.2/R69.3,R0.0/R1.9
Award Date11/16/2016
Closeout Date10/29/2020
Work DescriptionROADWAY REHABILITATION AND BRIDGE CONSTRUCTION.
Location DescriptionSAN LUIS OBISPO AND MONTERY COUNTIES NEAR PASO ROBLES FROM 0.5 MILE SOUTH OF SAN MARCOS CREEK BRIDGE TO 0.2 MILE SOUTH OF BRADLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 09/15/2016)

Sample Information

Sample Taken Date12/20/2017 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/22/2017
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedDistributor
First name of sampler or witnessed byJames Last name of sampler or witnessed byPalmer
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameAlamillo Rebar Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Nucor
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size8 Coupler ModelA2 Lenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L9077, L8942, L9081, L9043 Rebar Heat Number(s)232117, PL16207340
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-12-20-10
DIME Test ID: 2017-12-20-10-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-01-02

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/26/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#8/25mm0.7906975188292Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 12/26/2017