Summary for Test 2025-11-06-38-3
Test performed: ASTM D2628-91r16Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/06/2025 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/13/2025 |
| Sample type | Stock | A brief description of the sample | 3.75" Elastomeric Joint Seal |
| The quantity of what the sample constitutes | 550 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Watson Bowman Acme Corp | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 2625400 |
|---|---|---|---|
| Manufacturer(s) | Watson Bowman Acme Corp | Temperature | 72 |
| Humidity | 50 | Comments | |
| Joint Seal Size | 3.75 |
Test Details
DIME Sample ID: 2025-11-06-38
DIME Test ID: 2025-11-06-38-3
Testing Lab: Phoenix National Lab
Test Method: ASTM D2628-91r16: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements
Test Release Date: 2025-12-04
Test Results
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 12/03/2025
High or low tempurature: Low
Temperature: 0 f
Humidity: 0 %
Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ): 3.75 in
Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ): 3.131 in
Percent Recovery: 83 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/4/2025 ✔
