Summary for Test 2017-12-22-12-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 12/22/2017 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/22/2017 |
Sample type | Verification | A brief description of the sample | 3 4 in Aggregate Sample |
The quantity of what the sample constitutes | Unknown Quantity | From where was the sample collected | Source |
First name of sampler or witnessed by | Aggregate First Name | Last name of sampler or witnessed by | Aggregate Last Name |
Title of sampler | Aggregate Engineer | Telephone number of sampler | 7753550420 |
Laboratory sample identification | Aggregate Sample ID | Linked DIME Sample ID | Aggregate DIME Sample ID |
The fabricator/manufacturer/facility name | SNC Mustang Pit Sparks NV | Transportation Laboratory (TL) Number | Aggregate TL Number |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Aggregate TL Form | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Aggregate Source ID |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | SNC Mustang Pit Sparks NV | The fabricator/manufacturer designation for the sample | SNC Mustang Pit Sparks NV |
The plant number | 99999 | A detailed description of where the material sample was collected | Coarse aggregate pile at source |
Where the material sample would have been placed if not sampled | 7753550420 | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2017-12-22-12
DIME Test ID: 2017-12-22-12-1
Testing Lab: CT HQ - QAM Sacramento Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2017-12-29
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 12/22/2017
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 94.5 %
Cumulative percent passing the 1/2 in. sieve: 81.3 %
Cumulative percent passing the 3/8 in. sieve: 69.5 %
Cumulative percent passing the 1/4 in. sieve: 69.5 %
Cumulative percent passing the #4 sieve: 44.3 %
Cumulative percent passing the #8 sieve: 30.3 %
Cumulative percent passing the #16 sieve: 21.6 %
Cumulative percent passing the #30 sieve: 15.6 %
Cumulative percent passing the #50 sieve: 10 %
Cumulative percent passing the #100 sieve: 6 %
Cumulative percent passing the #200 sieve: 4.03 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/22/2017 ✔