Summary for Test 2025-11-25-27-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000300
DEA: 060S0504
EFIS: 0615000047
DIST-CO-RTE-PM06-KER-166-17.5
Award Date08/23/2024
Closeout DateNot set
Work DescriptionMICROPILING, STRUCTURAL CONCRETE, AND HOT MIX ASPHALT (TYPE A).
Location DescriptionKERN COUNTY NEAR METTLER AT CALIFORNIA AQUEDUCT BRIDGE
QA Service Level1 (Verified on 05/06/2024)

Sample Information

Sample Taken Date11/25/2025 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/26/2025
Sample typeAcceptance A brief description of the sample4x8 cylinders
The quantity of what the sample constitutes12 concrete cylinders 4X8 From where was the sample collectedJob Site
First name of sampler or witnessed byMilo Last name of sampler or witnessed byGUINTO
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3912292

Material Information

Material TypeConcrete The concrete mix design numberND19551
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-11-25-27
DIME Test ID: 2025-11-25-27-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-12-02

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Barrett Felder
Date of test: 12/02/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 57520 lb
Maximum load on cylinder 2: 58100 lb
Maximum load on cylinder 3: 59240 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4554.2 psi
Compressive strength of cylinder 2: 4622.1 psi
Compressive strength of cylinder 3: 4690.4 psi
Compressive strength (to nearest 10 psi): 4620 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0S0504_37037_251125_7D_MGpdf252.24 KB12/02/20252025-11-25-27-1   Info

Test was verified on 12/2/2025