Summary for Test 2017-12-22-11-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date12/22/2017 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing12/22/2017 Sample typeQuality Control
A brief description of the sampleHMA Sample The quantity of what the sample constitutesUnknown Quantity
From where was the sample collectedSource First name of sampler or witnessed byHMA First Name
Last name of sampler or witnessed byHMA Last Name Title of samplerHMA Engineer
Telephone number of sampler7753550420 Laboratory sample identificationHMA Sample ID
Linked DIME Sample IDHMA DIME Sample ID The fabricator/manufacturer/facility nameSierra Nevada Construction
Transportation Laboratory (TL) NumberHMA TL Number Inspector Lot Number from the Transportation Laboratory (TL) FormHMA TL Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2017-12-22-11
DIME Test ID: 2017-12-22-11-3
Testing Lab: CT HQ - QAM Sacramento Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2017-12-29

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 12/22/2017
Specific Gravity for Sample 1: 2.518
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/22/2017 ✔